A user asked if it was possible and recommended to install the real-time agent on a monitor server to run a stress level calculation script. Another user confirmed that this is possible and recommended. However, when attempting to run the "ControlUp Stress Calculator v2 Metrics Explorer (Draft)" script, an error occurred stating that a required module was not found. The solution was to open a support ticket. The article that discusses this feature can be found at https://support.controlup.com/docs/stress-level-calculator-tool-v2
Read the entire ‘Installing Real-Time Agent on Monitor Server for Stress Level Calculation’ thread below:
Hi all, is it possible and recommended to install the real-time agent on a monitor server, e.g. to run the Stress Level Calculation script? As it is described in this article: https://support.controlup.com/docs/stress-level-calculator-tool-v2
You can install the agent for sure on a monitor and it’s indeed recommended to do so.
All right, thanks a lot.
Now when I run "ControlUp Stress Calculator v2 Metrics Explorer (Draft)" on one of my monitor server, I get the following error message:
Import-ControlUpModule : The required module was not found. Please make sure COntrolUP.CLI Module is installed and
available for the user running the script.
At C:\ProgramData\Smart-X\ControlUp\Scripts\018ac8b1-2221-40e8-951f-aee71db094f9.ps1:750 char:1
What’s wrong?
that can only happen if there’s no monitor installed. Please open a support ticket so they can help you with it
Continue reading and comment on the thread ‘Installing Real-Time Agent on Monitor Server for Stress Level Calculation’. Not a member? Join Here!
Categories: All Archives, ControlUp for VDI, ControlUp Scripts & Triggers